![Lynx NGT-9000 Series Скачать руководство пользователя страница 144](http://html1.mh-extra.com/html/lynx/ngt-9000-series/ngt-9000-series_installation-manual_1953763144.webp)
Lynx NGT-9000s
Installation Manual
Table 4-3: List of Fault Log Messages
FAULT ID/ CODE
(HEX)
FAULT DESCRIPTION
CORRECTIVE ACTION
0x00003009
1030 Rcvr Top PIN Isolation Failure
Transponder Internal failure
TAS Internal failure
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x0000300A
1030 Rcvr Btm TR Isolation Failure
Transponder Internal failure
TAS Internal failure
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x0000300B
1030 Rcvr Top TR Isolation Failure
Transponder Internal failure
TAS Internal failure
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x0000300C
1030 XPDR ATCRBS Receiver
Failure
Transponder Internal failure
TAS Internal failure
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x0000300D
XPDR 1090 XMIT Bottom Power
Failure
Transponder Internal failure
ADS-B Internal failure
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x0000300E
XPDR 1090 XMIT Top Power Failure
Transponder Internal failure
ADS-B Internal failure
Reboot the unit and check if the fault
persists. Contact L-3 Field Service before
removal.
0x00003801
Clear Invalid Mode S Address
Log the fault.
0x00003802
Clear FPGA 1090 Transmission
Failure
Log the fault.
0x00003803
Clear Squitter rate failure
Log the fault.
0x00003804
Clear Squitter scheduler process not
running at expected rate
Log the fault.
0x00003805
Clear 1090 ATCRBS rx
Failure(without TAS antenna)
Log the fault.
0x00003806
Clear 1030 Rcvr Btm Power Failure Log the fault.
0x00003807
Clear 1030 Rcvr Top Power Failure
Log the fault.
0x00003808
Clear 1030 Rcvr Btm PIN Isolation
Failure
Log the fault.
0x00003809
Clear 1030 Rcvr Top PIN Isolation
Failure
Log the fault.
0x0000380A
Clear 1030 Rcvr Btm TR Isolation
Failure
Log the fault.
0x0000380B
Clear 1030 Rcvr Top TR Isolation
Failure
Log the fault.
0x0000380C
Clear 1030 XPDR ATCRBS
Receiver Failure
Log the fault.
0x0000380D
Clear XPDR 1090 XMIT Bottom
Power Failure
Log the fault.
Page 4-24
Maintenance
0040-17001-01
January 15, 2015
Revision A