3.6 VERIFY SOFTWARE VERSION
The Maintenance PC (MPC) and Maintenance Application Tool (Lynx MAT) are used to interface with
the unit to load software/firmware/databases, view factory / version data, and retrieve fault / event logs.
These procedures assume the following:
•
Power is being supplied to the aircraft and unit.
•
The Lynx MAT is active on the MPC.
•
The MPC is connected to the unit via the USB interface
•
The MPC and unit are communicating. From the Lynx MAT panel select
Connect
Z
NGT9000
Z
USB. This is required each time the unit power is cycled.
1.
From the Lynx MAT select Info
Z
Versions. See Figure 3-8.
2.
Use the versions screen to verify that the field loadable software is correct for this installation.
Details on software part numbers and versions are available in the General Information section under
paragraph heading “Software Versions”.
•
If a software version is found to be incorrect, update using the procedures located in the
maintenance section of this manual.
Figure 3-8: Lynx MAT – Check Versions
Page 3-8
Installation Checkout
0040-17001-01
January 15, 2015