GRAFIK Eye
®
QS Control Unit Installation and Operation Guide 4
Wiring the GRAFIK Eye
®
QS Control Unit
Overview of Line Voltage/Mains Wiring
1234
12
ABC
1 2 3 4 5 6 L N
12 AWG (4.0 mm
2
)
each terminal
120 - 127 V
~
or
220 - 240 V
~
Distribution
Panel
Line Voltage/Mains
Cables and Load Wiring
1 2 3 4 5 6 L N
Incandescent load
Load controlled
by power module
or interface
Terminal labels:
L: Hot/Live
N: Neutral
: Ground
1-6: Dimmed/Switched
line voltage outputs
Power module
or interface