Reference:
“Procedure 6-2: Connect personal computer
............................................................................................................................................................
5
Are you successfully logged into the remote shelf?
If...
Then...
Yes
Continue with
No
The remote/neighbor SYSCTL is
possibly failed. Proceed to
6-3: Replace a SYSCTL (VLNC1)
circuit pack” (6-35)
............................................................................................................................................................
6
From the System View of the remote shelf, click the
Alarm List
button.
............................................................................................................................................................
7
Is there
section DCC channel failed
alarm or
inc. OCN
alarm
present?
If...
Then...
Yes
Proceed to
Or
Then continue with
No
Proceed to
............................................................................................................................................................
8
From the System View of the remote NE, click the
Alarm List
button
and click
Refresh
.
Procedure 5-42: Clear
″
neighbor SYSCTL
CP unavailable (nbr tid = TID)
″
alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 1 2 6
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005