Procedure 6-2: Connect personal computer (PC) and establish
WaveStar
®
CIT session
....................................................................................................................................................................................................................................
Overview
Use this procedure to connect PC and establish a WaveStar
®
CIT
session.
Required equipment
At least one of the following cables is required:
•
RS-232 cable with an RJ-45 connector on one end and a PC
serial connector on the other (typically DB9) for the
RS232
port.
•
CAT5 Ethernet straight-through or a cross-over cable for the
LAN
port. If you are connecting the PC directly to the NE, use the
LAN 10Base-T cross-over cable. If you are connecting the PC
directly to a hub, use the LAN 10Base-T straight-through cable.
For detailed cabling information, refer to the Metropolis
®
DMXplore
Access Multiplexer Installation Manual, 365-372-334.
Important! You must be a member of either the Administrator
Group or the Power User Group on your PC to establish a
WaveStar
®
CIT session.
This procedure assumes that TCP/IP and OSI connectivity has
been established to the required network elements in the network.
Before you begin
Prior to performing this procedure:
1.
Refer to
“Procedure 6-1: Install generic and WaveStar
.
2.
Refer to
“Electrostatic discharge” (1-13)
in
3.
If WaveStar
®
CIT logins were enabled during installation, obtain
a valid user ID and password for the WaveStar
®
CIT.
4.
Obtain a valid user ID and password for the required network
element.
5.
Obtain the Target Identifier (TID)/NE name of the network
element that you are establishing a WaveStar
®
CIT session with.
Supporting procedures
....................................................................................................................................................................................................................................
6 - 2 4
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005