Disengage the affected Ethernet circuit pack completely from the
shelf.
1.
Release the circuit pack faceplate latch.
2.
Extract the circuit pack from the shelf, fully disconnecting it
from the backplane, and therefore removing power.
Result:
The
ACTIVE
and
FAULT
LED on the pack extinguish.
3.
Re-seat the Ethernet circuit pack in the shelf and wait
approximately 5 minutes.
............................................................................................................................................................
4
From the System View, click the
Alarm List
button and click
Refresh
.
............................................................................................................................................................
5
Is the
FE-LAN CP failed
alarm still present?
If...
Then...
Yes
Continue with the next step.
No
STOP! End of Procedure.
............................................................................................................................................................
6
Replace the affected Ethernet circuit pack.
Reference:
“Procedure 6-5: Replace Ethernet circuit pack”
............................................................................................................................................................
7
From the System View, click the
Alarm List
button and click
Refresh
.
............................................................................................................................................................
8
Is the
FE-LAN CP failed
alarm still present?
If...
Then...
Yes
Contact your next level of support.
No
STOP! End of Procedure.
E
N D
O F
S
T E P S
..............................................................................................................................................................................
Procedure 5-19: Clear
″
FE-LAN CP failed
″
alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies