Procedure 5-27: Clear
″
inc. FE-LAN ANM
″
alarm
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear an
inc. FE-LAN ANM
alarm indicated
by a lighted Critical/Major (
CR/MJ
) or Minor (
MN/ABN
) LED on the
SYSCTL faceplate and reported as critical, major, minor, or Not
Alarmed in the WaveStar
®
CIT Alarm List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear an
inc. FE-LAN ANM
alarm.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the
inc. FE-LAN ANM
alarm in the resulting alarm list.
............................................................................................................................................................
2
Refer to the Probable Cause column in the alarm list, and determine
which circuit pack is affected by the
inc. FE-LAN ANM
alarm and
note the corresponding AID.
............................................................................................................................................................
3
From the System View menu, select
View
→
Equipment
, expand the
required circuit pack, highlight the alarmed port, and click
Select
.
Then click the Port Data tab.
Result:
The port parameters appear.
............................................................................................................................................................
4
Record the following information:
•
Provisioned Duplex Mode
•
Actual Duplex Mode Operation
•
Provisioned Line Rate
•
Actual Line Rate Operation
............................................................................................................................................................
5
From the View Equipment window, click Flow Control tab.
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 8 1