This encoder allows to choose between the following current output range
options (
= CURRENT):
Application range
minimum position
maximum position
4 mA ... 20 mA
4 mA
20 mA
0 mA … 20 mA
0 mA
20 mA
0 mA … 24 mA
0 mA
24 mA
When the default parameters are set (EM5812/16384PA), increments per each
step are as follows:
0.244 µA
= 4 mA ... 20 mA
0.305 µA
= 0 mA … 20 mA
0.366 µA
= 0 mA … 24 mA
4.11 Voltage analogue output
+Vout delivers the voltage analogue signal.
After having enabled the analogue output by setting the
parameter in the
ENCODER CONFIGURATION
box of the
CONFIGURATION
page, the user is allowed to choose the type of output (either current or voltage)
by setting the desired value (CURRENT or VOLTAGE) next to the
parameter in the same box; then he has to set the output range by means of the
drop-down list in the following parameter
This encoder allows to choose between the following voltage output range
options (
= VOLTAGE):
Application range
minimum position
maximum position
0 V ... +5 V
0 V
+5 V
0 V ... +10 V
0 V
+10 V
- 5 V … +5 V
-5 V
+5 V
-10 V … +10 V
-10 V
+10 V