EM58 PA
Programming mode: Prog (single ramp)
Press the
button to enter the PROG programming mode and activate the
relevant functions. In this mode
the travel will be defined in a single ramp
.
The PROG (single ramp) programming mode allows to programme the encoder
provided that you know exactly the number of encoder information (counts) for
the physical travel of the application you need to measure and control; the
travel is defined in a single ramp, the initial position of the travel is the
minimum value of the output range, the final position is the maximum value of
the output range; beyond the travel limits the current / voltage signal level is
kept at the minimum / maximum value of the selected range (
).
The length of the travel you need to measure and control must be set next to
the
item and is expressed in counts. The set output range
(the overall information to be output which is set next to the
item) is defined over the travel of the application and is comprised between the
ends of the axis. For the positions beyond the travel limits the current / voltage
signal level will be kept at the minimum / maximum value of the selected range.
Before the initial position of the travel the encoder will provide the minimum
current / voltage signal level of the output range selected in the
parameter; after the last position of the travel the encoder will provide the
maximum current / voltage signal level of the output range selected in the
parameter.