EM58 PA
NOTE
Encoders with T12 cable output require IF92 converter only.
Please note that the configuration parameters of the serial port have fixed
values so the user cannot change them.
They are:
RS-232 serial port settings
Value
Baud rate
9600
Byte size
8
Parity
None
Stop bits
1
Flow control
None
4.8 0Vdc
0Vdc RS-232, 0Vdc analogue and 0Vdc Power Supply are internally connected.
4.9 Fault output
This output is only available if the current output is enabled (
CURRENT). It is intended to signal an error such as a circuit break. As soon as the
Fault signal is activated, a message is also invoked to appear in the
DIAGNOSTICS
box of the
CONFIGURATION
page (see the error message
).
To connect the Fault signal please refer to the examples hereafter: “4.9.1 Fault
output connected to a PLC input“ and “4.9.2 Fault output connected to a relay“.
Please pay attention to the value of the R2 resistor (Figure 2 and Figure 3).
Imax = 50 mA
R1 = 47
R1
I
Vdc
R2
No encoder error = transistor ON (conducting)
Encoder error = transistor OFF (open)
MAN EM58 PA E 1.1
Electrical connection
20 of 60