EM58 PA
Programming mode: Prog (cyclic ramp)
Press the
button to enter the PROG programming mode and activate the
relevant functions. In this mode
the travel will be defined in cyclic ramps
.
The PROG (cyclic ramp) programming mode allows to programme the encoder
provided that you know exactly the number of encoder information (counts) for
the physical travel of the application you need to measure and control; the
travel is defined in a ramp which is then repeated cyclically: as soon as the the
final position of the travel is reached, then the minimum signal level of the
selected range is output to start a new ramp; and so on. The initial position of
the travel is the minimum value of the selected output range (
),
the final position is the maximum value of the output range. The length of the
travel you need to measure and control must be set next to the
item and is expressed in counts. The set output range (the overall
information to be output which is set next to the
item) is defined
over the travel of the application and is comprised between the ends of the axis.
Ramps follow each other, i.e. they are repeated cyclically. If you move the axis
beyond the limits of the travel you enter either the previous or the following
ramp.
MAN EM58 PA E 1.1
Software and configuration parameters
50 of 60