EM58 PA
Programming mode: Start / Stop (single ramp)
Press the
button to enter the START / STOP (single ramp) programming
mode and activate the relevant functions. In this mode
the travel will be
defined in a single ramp
.
The START / STOP (single ramp) programming mode allows to programme the
encoder by considering directly the physical travel of the application you need
to measure and control; the travel is defined in a single ramp, the initial position
of the travel is the minimum value of the output range, the final position is the
maximum value of the output range; beyond the travel limits the current /
voltage signal level is kept at the minimum / maximum value of the selected
range. The set output range (the overall information to be output which is set
next to the
item) is defined over the travel of the specific
application and is comprised between the ends of the axis: the origin of the axis,
i.e. the point where you press the
the axis, i.e. the point where you press the
positions beyond the travel limits the current / voltage signal level will be kept
at the minimum / maximum value of the selected range. Before the initial
position of the travel the encoder will provide the minimum current / voltage
signal level of the output range selected in the
the last position of the travel the encoder will provide the maximum current /
voltage signal level of the output range selected in the
parameter.
MAN EM58 PA E 1.1
Software and configuration parameters
41 of 60