2. Control System List
7
Multi V 5
Control System
Category
Controller
name
Model name
Compatible
Product
Dimensions
(W x H x D, mm)
Feature
Central
controller
AC Smart 5
PACS5A000
All IDU
ERV
1)
ERV DX
Heating
AHU
Chiller*
253.2 x 167.7 x 28.9
• 10.2 inch color Display
• Touch Screen
• DC 12 V Adaptor
• Max 128 indoor unit control
• RS-485 : 2 channels
CH1 :
- LGAP(AHU) or
- Modbus(AHU, Chiller, ACS I/O)
- Indoor unit
2)
(AC Smart5 only
3)
)
CH2 : Indoor unit
2)
• DI 2EA, DO 2EA
AC Smart IV
/
AC Smart
BACnet
PACS4B000
/
PBACNA000
AC Ez Touch
PACEZA000
All IDU
ERV
1)
ERV DX
Heating
137x 121 x 25
• 5inch color Display
• Touch Screen
• DC 12 V Adaptor
• Max 64 indoor unit control
• RS-485 : 1 channel
• DI 1EA
(Emergency stop Only)
AC Ez
PQCSZ250S0
All IDU
ERV
1)
ERV DX
190 x 120 x 20
• TN Mono Display & 18 LED
• Button Control
• DC 12 V
• Max 32 indoor unit control
• RS-485 : 1 channel
PDI Premium
PQNUD1S40
All IDU
ERV DX
Heating
[Controller]
270 x 155 x 65
[Power Module]
120 x 155 x 65
• EHP ODU 8EA(GHP 4EA)
• 128 EHP Indoor Units
(64 GHP Indoor Units)
• AC 220~240 V Power Input
• 8port Pulse Input
PDI Standard
PPWRDB000
All IDU
ERV DX
Heating
[Controller]
270 x 155 x 65
[Power Module]
120 x 155 x 65
• EHP ODU 2EA(GHP 1EA)
• 128 EHP Indoor Units
(64 GHP Indoor Units)
• AC 220~240 V Power Input
• 2port Pulse Input
Interface
Device
ACS I/O Module
PEXPMB000
ACP 5
ACP IV
AC Smart 5
AC Smart IV
126 x 155 x 65
• 24 V~ Power Input
• AO 4EA (Voltage)
• UI 4EA
(Voltage, Current, NTC 10k,
PT1000, Ni1000, Dry Contact)
• DI 3EA (Dry Contact)
• DO 3EA
(Relay Output / Normal Open)
• RS-485 : 1 channel(Modbus)
• * It needs to apply Chiller Option KIT.
• 1) ERV : Energy Recovery Ventilation
• 2) Indoor unit : IDU, ERV, DX ERV, Heating
• 3) In case of using AC Smart IV or AC Smart BACnet, can’t use CH1 for Indoor unit.
• If you need more detail, please refer to the Control PDB or the manual of product.
(http://partner.lge.com/global : Home> Doc.Library> Product > Control(BECON))
Содержание ARUM080LTE5
Страница 1: ...Heat Recovery Heat Pump R410A 50Hz 60Hz 0CVV0 01E Replaces 0CVV0 01D P No MFL67474071 ...
Страница 85: ...78 Multi V 5 Outdoor Units 4 Wiring Diagrams 4 1 8 10 12 HP UXA 1 Comp ...
Страница 86: ...4 Wiring Diagrams 79 Multi V 5 Outdoor Units 4 2 14 16 HP UXB 1 Comp ...
Страница 87: ...Multi V 5 4 Wiring Diagrams 80 Outdoor Units 4 3 18 20 22 24 26HP UXB 2 Comp ...
Страница 703: ...5 Multi V 5 Heat Recovery HR Unit 3 Dimensions PRHR023 PRHR033 PRHR043 481 176 125 311 150 150 486 500 218 40 55 19 ...
Страница 704: ...Multi V 5 Heat Recovery 3 Dimensions 6 HR Unit PRHR063 PRHR083 809 218 55 40 19 793 160 160 481 176 311 125 ...
Страница 766: ...Special Guide Multi V 5 1 Cautions for Refrigerant Leaks 2 Guide for installing at seaside ...