1. Specifications
37
Multi V 5
Outdoor Units
Protection
Devices
High pressure protection
High pressure sensor /
High pressure switch
High pressure sensor /
High pressure switch
Compressor/Fan
Over-heat protection /
Fan driver overload protector
Over-heat protection /
Fan driver overload protector
Inverter
Over-heat protection /
Over-current protection
Over-heat protection /
Over-current protection
Communication Cable (VCTF-SB)
No.×
㎟
2C × 1.0 ~ 1.5
2C × 1.0 ~ 1.5
Refrigerant
Refrigerant name
R410A
R410A
Precharged Amount
kg
50.0
51.0
lbs
110.2
112.4
t-CO
2
eq
104.4
106.5
Control
Electronic Expansion Valve
Electronic Expansion Valve
Power Supply
V, Ø, Hz
380-400-415, 3, 50/60
380-400-415, 3, 50/60
Running
Current
Cooling
A
75.10 - 71.35 - 68.77
77.98 - 74.08 - 71.40
Heating
A
88.81 - 84.37 - 81.32
92.13 - 87.53 - 84.36
Number of maximum connectable indoor units ***
64
64
HP
70
72
Model Name
Combination Unit
ARUM700LTE5
ARUM720LTE5
Independent Unit
ARUM240LTE5
ARUM240LTE5
ARUM240LTE5
ARUM240LTE5
ARUM220LTE5
ARUM240LTE5
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the semi-anechoic rooms by ISO 9614 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
4. Sound values of combination model are calculated values based on sound results of independent models.
Sound values can be increased owing to ambient or installation conditions during operation.
Sound values of system [dB(A)] = 10*log [10^(A1/10)+ ... +10^(An/10)] , A1~An means sound values of independent models.
5. Performances are in accordance with ISO 15042.
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
6. *** : The number in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160~200%).
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)
8. #1 : Heat Recovery system, #2 : Heat Pump system
Содержание ARUM080LTE5
Страница 1: ...Heat Recovery Heat Pump R410A 50Hz 60Hz 0CVV0 01E Replaces 0CVV0 01D P No MFL67474071 ...
Страница 85: ...78 Multi V 5 Outdoor Units 4 Wiring Diagrams 4 1 8 10 12 HP UXA 1 Comp ...
Страница 86: ...4 Wiring Diagrams 79 Multi V 5 Outdoor Units 4 2 14 16 HP UXB 1 Comp ...
Страница 87: ...Multi V 5 4 Wiring Diagrams 80 Outdoor Units 4 3 18 20 22 24 26HP UXB 2 Comp ...
Страница 703: ...5 Multi V 5 Heat Recovery HR Unit 3 Dimensions PRHR023 PRHR033 PRHR043 481 176 125 311 150 150 486 500 218 40 55 19 ...
Страница 704: ...Multi V 5 Heat Recovery 3 Dimensions 6 HR Unit PRHR063 PRHR083 809 218 55 40 19 793 160 160 481 176 311 125 ...
Страница 766: ...Special Guide Multi V 5 1 Cautions for Refrigerant Leaks 2 Guide for installing at seaside ...