189
Technical Data
Leica TPS800-4.0.0en
Distance measurement (without reflector)
•
Range of measurement:
Power..................................... 1.5 m to >400 m
Ultra ..................................... 1.5 m to >1000 m
•
Display unambiguous:........................ to 760 m
•
Prism constant (additive constant):. + 34.4 mm
*
Kodak Grey Card used with exposure meter for
reflected light
4) Object in strong sunlight, severe heat shimmer
5) Object in shade, or sky overcast
6) Day, night and twilight
** Standard deviation acc. to ISO 17123-4; beam
interruptions, severe heat shimmer and moving
objects within the beam path can result in deviations
of the specified accuracy.
*** Accuracy and measure time depend on atmo-
spheric conditions, target object and observation
situation.
Power: Range (without reflector)
Atmospheric
conditions
No reflector
(white target)*
No reflector
(grey, albedo 0.25)
4
200 m (660 ft)
100 m (330 ft)
5
300 m (990 ft)
150 m (430 ft)
6
>400 m (>1310 ft)
>200 m (>660 ft)
Ultra: Range (without reflector)
Atmospheric
conditions
No reflector
(white target)*
No reflector
(grey, albedo 0.25)
4
600 m (1970 ft)
300 m (990 ft)
5
800 m (2630 ft)
400 m (1310 ft)
6
>1000 m
(>3280 ft)
>500 m (>1640 ft)
EDM
measuring
program
Accuracy
Time per
measurement
Standard**
0 - 500 m
2 mm + 2 ppm
typ. 3 - 6 s
max. 12 s
> 500 m
4 mm + 2 ppm
Tracking***
5 mm + 3 ppm
typ. 0.25 s