152
Check & Adjust
Leica TPS800-4.0.0en
Warnings / Messages
Important Messages
Meaning
Measures
V-Angle not suitable for
adjustment (Check V-angle
or face) !
Aiming tolerance not met or telescope posi-
tion/face not changed.
Aim on the target point with an accuracy of
min. 5 gon. The target point must be
approximately in the horizontal plane.
Confirmation of the message required.
Adjustment result out of
tolerance. Previous values
retained !
Computed values out of tolerance.
Previous values retained.
Repeat measurements.
Confirmation of the message required.
Hz-Angle out of limit !
Hz-angle in second face/telescope pos.
deviates more than 5 gon from the target
point.
Aim on the target point with an accuracy of
min. 5 gon.
Confirmation of the message required.
Measurement Error. Try
again.
Measurement error appeared (e.g. instable
set up or period between measuring in tele-
scope position I and II too long).
Repeat the process.
Confirmation of the message required.