50
Programs
Leica TPS800-4.0.0en
Orientation coordinates can be either obtained from
the internal memory or entered manually.
After each measurement you are asked wether to
proceed or not. Answering with yes brings you back
to the Measurement dialog, to take an additional
measurement. Answering with no brings you to the
Result dialog.
1/I
Status indication; shows that first point was
measured in telescope position I.
1/I II
First point measured in telescope position I
and II.
S
Hz:
After the first measurement the finding of
other target points (or the same point when
changing the telescope position) is easier
by setting the indicated angle difference
near to 0°00'00" by turning the instrument.
S
: Difference between horizontal distance to
target point computed from coordinates and
the measured distance.
Display of computed orientation
[OK]
Set computed Hz-orientation.
IR
I
ALL
DIST
REC
EDM
PtID :
201
hr :
1.300 m
BsBrg: 236°56'14"
Hz :
51°12'23"
:
0.569 m
SIGHT TARGET POINT 3/I II
I
PREV
RESID
OK
NoPts. :
2
Station :
200
HzCor :
123°00'23"
StDev :
±
0°00'08"
ORIENTATION RESULT