120
Programs
Leica TPS800-4.0.0en
Measure the backsight point.
After the measurement with [ALL] or [DIST] + [REC],
depending on the configured traverse method,
either the Sight Backsight Point panel stays active
for measuring the backsight point in a second face
or the Sight Foresight Point panel appears for
measuring the foresight point.
6. Measuring a foresight point
A point ID for the foresight point is suggested but
can be changed.
Measure the foresight point.
After the measurement with [ALL] or [DIST] + [REC],
depending on the configured traverse method,
either the Sight Foresight Point panel stays active
for measuring the foresight point in a second face or
the Sight Backsight Point panel appears for
measuring the backsight point is displayed.
7. Repetitive loop for the number of sets
Alternating between panels for the backsight and
foresight measurements continues according to the
configured number of sets.
The number of sets and the face are indicated in the
top right corner of the panel. For example 1/I means
set 1 in face I.
Interrupting a set
[ESC]
Quits the backsight and foresight
panel.
This panel is displayed:
ALL
DIST
REC
Sight Backsight! 1/l
Stat. ID : 1200
BS ID : 1001
hr : 1.500 m
Code :
------
Hz :
0.0000 g
V :
0.0000 g
:
0.0000 m
IR
I