123
Programs
Leica TPS800-4.0.0en
7.3 Check Point
)
A check point is excluded from the traverse
calculation and adjustment. However all measure-
ment data and results observed from a check point
are stored.
Input the name of the check point and the height of
the reflector. Use the functions [FIND], [LIST] or
[ENH] as described in 3. Entering station data.
Press [OK] to go to the next panel.
Measure the check point. The deltas in Easting,
Northing and Height are displayed.
If the tolerances defined in the TraversePRO config-
uration are exceeded, an information message is
displayed.
8. Closing a traverse
Press [CLOSE] in the Sight Foresight Point panel
before measuring a foresight point after a backsight
point measurement.
The options for closing a traverse are:
Use when you are setup on the closing
station, you know its coordinates and the
coordinates of the closing point.
1. Input the data for both points.
2. Measure to the closing point.
3. The results are displayed.
)
If you chose this method you are
forced to do a distance measurement.
F1
F2
F3
F4
F1 At known Station
CLOSE TRAVERSE...
to known Closing Point
F2 To known Closing Point
F3 At known Station only
F4 Leave open