Effective gain of a voltage or current probe can be set from /1000 attenuation to X10,000 gain.
Current Input Setup Menus
Adjusting Current with No Amplifier Normalization Factor
When a non-ProBus current probe is used that has no normalization factor, proceed as follows:
1.
Touch the
Current
tab.
2.
Touch inside the
Current probe type
field and select
Probe
from the pop-up menu.
3.
Touch inside the
Attenuation
field and select
Variable
from the pop-up menu.
4.
Determine the probe’s effective gain factor, then touch inside the
Effective Gain
field.
Enter that value using the pop-up keypad.
5.
If the current probe’s DC offset cannot be adjusted to zero on the probe, use the
Fine
Adjust DC Level
to correct the level.
Adjusting Current When the Current Probe Has an Amplifier with a 10 mV/div Normalization
Factor
This setup is useful for the AM503 amplifier and its family of current probes.
1.
Touch the
Current
tab.
2.
Touch inside the
Current probe type
field and select
Amplifier 10mV/div
from the pop-
up menu; the
Amps/div
field appears.
3.
Touch inside the
Amps/div
field and enter a value, using the pop-up keypad.
4.
If the current probe’s DC offset cannot be adjusted to zero on the probe, use the
Fine
Adjust DC Level
to correct the level.
Содержание 6000 SERIES
Страница 59: ...WR6K OM E Rev A ISSUED October 2003 57 4 Select a language 5 Click Next when the Wizard appears ...
Страница 60: ...Operator s Manual 58 ISSUED October 2003 WR6K OM E Rev A 6 Select Complete setup 7 Click Install ...
Страница 65: ...WR6K OM E Rev A ISSUED October 2003 63 Proper Orientation of Drive ...
Страница 131: ...WR6K OM E Rev A ISSUED October 2003 129 Example ...
Страница 141: ...WR6K OM E Rev A ISSUED October 2003 139 ...
Страница 236: ...Operator s Manual 234 ISSUED October 2003 WR6K OM E Rev A Example 6 ...
Страница 247: ...WR6K OM E Rev A ISSUED October 2003 245 In this figure the panel has been pasted onto the Excel sheet for comparison ...
Страница 261: ...WR6K OM E Rev A ISSUED October 2003 259 ...
Страница 286: ...Operator s Manual 284 ISSUED October 2003 WR6K OM E Rev A ...
Страница 304: ...Operator s Manual 302 ISSUED October 2003 WR6K OM E Rev A ...
Страница 307: ...WR6K OM E Rev A ISSUED October 2003 305 Convolve two signals ...
Страница 327: ...WR6K OM E Rev A ISSUED October 2003 325 How JitterTrack s Interval Error works when Clock Mode is selected ...
Страница 348: ...Operator s Manual 346 ISSUED October 2003 WR6K OM E Rev A ...
Страница 398: ...Operator s Manual 396 ISSUED October 2003 WR6K OM E Rev A Setting Up the Line Voltage and Current Signals ...
Страница 402: ...Operator s Manual 400 ISSUED October 2003 WR6K OM E Rev A ...