Operator's Manual
360
ISSUED: October 2003
WR6K-OM-E Rev A
PMA2 OPTION
INTRODUCTION TO PMA2
The Tools and What They Do
When combined with a LeCroy digital storage oscilloscope (DSO) and current and differential
measurement tools, the PowerMeasure Analysis 2 (PMA2) software package provides a
complete set of hardware and software tools for the design and analysis of power conversion
circuits, as well as current and differential voltage measurement tools. PMA2 consists of three
major measurement areas:
Power Device Analysis
– This area covers measurements made on power switching devices
used in power conversion products, such as power supplies, electronic motor drives (adjustable-
speed drives), or high-efficiency lighting circuits. Measurements covered include device
instantaneous power, safe operating area (SOA), saturation voltage, and dynamic on-resistance.
With PMA2, these device measurements can be made either on a test stand or in circuit while the
devices are operating in a power conversion system.
Modulation Analysis
– This area covers the acquisition and analysis of information contained in
a power conversion circuit’s modulated control signal. It analyzes modulation changes in pulse
width (PWM), duty cycle, frequency, or period as the circuit responds to changes in line and/or
load, as well as during start-up and shut-down.
Line Power Analysis
– This area covers the measurement of line voltage and current applied to
an off-line power conversion device. Real power, apparent power, power factor, and line
harmonics are measured. Analysis of line harmonic content is included to assist the design and
evaluation engineer in designing for pre-compliance to EN 61000-3-2 requirements.
Equipment Required
DSO
PowerMeasure Analysis 2 software operates on any LeCroy X-Stream
DSO. For analysis of phenomenon requiring the acquisition of many
cycles, a DSO with a minimum memory of 1 Mpt per channel should be
used. Steady-state analysis can be accomplished with shorter record
lengths. Two acquisition channels are adequate for most measurements,
but a four-channel DSO is required if you want to analyze multiple
devices or to use complex triggering.
Voltage Probes
Since most voltage signals associated with power conversion circuits are
not ground related, differential measurement capability is required. To
carry out all the measurements covered in Using Power Device Analysis
the CMRR, CMR, Overdrive Recovery, and compensation flatness
performance of the LeCroy DA1855A differential amplifier and its
associated DXC series passive differential probes are required. The
measurements in Using Modulation Analysis and Using Line Power
Analysis can be made with medium-performance differential probes.
Содержание 6000 SERIES
Страница 59: ...WR6K OM E Rev A ISSUED October 2003 57 4 Select a language 5 Click Next when the Wizard appears ...
Страница 60: ...Operator s Manual 58 ISSUED October 2003 WR6K OM E Rev A 6 Select Complete setup 7 Click Install ...
Страница 65: ...WR6K OM E Rev A ISSUED October 2003 63 Proper Orientation of Drive ...
Страница 131: ...WR6K OM E Rev A ISSUED October 2003 129 Example ...
Страница 141: ...WR6K OM E Rev A ISSUED October 2003 139 ...
Страница 236: ...Operator s Manual 234 ISSUED October 2003 WR6K OM E Rev A Example 6 ...
Страница 247: ...WR6K OM E Rev A ISSUED October 2003 245 In this figure the panel has been pasted onto the Excel sheet for comparison ...
Страница 261: ...WR6K OM E Rev A ISSUED October 2003 259 ...
Страница 286: ...Operator s Manual 284 ISSUED October 2003 WR6K OM E Rev A ...
Страница 304: ...Operator s Manual 302 ISSUED October 2003 WR6K OM E Rev A ...
Страница 307: ...WR6K OM E Rev A ISSUED October 2003 305 Convolve two signals ...
Страница 327: ...WR6K OM E Rev A ISSUED October 2003 325 How JitterTrack s Interval Error works when Clock Mode is selected ...
Страница 348: ...Operator s Manual 346 ISSUED October 2003 WR6K OM E Rev A ...
Страница 398: ...Operator s Manual 396 ISSUED October 2003 WR6K OM E Rev A Setting Up the Line Voltage and Current Signals ...