WR6K-OM-E Rev A
ISSUED: October 2003
123
COMMUNICATING OVER THE NETWORK
The instrument uses Dynamic Host Configuration Protocol (DHCP) as its addressing protocol.
Therefore, there is no factory set IP address.
Windows Setups
If the instrument is to reside within a domain on your LAN, your IS administrator will have to
connect the DSO.
Guidelines for Working in Windows
Although the instrument has an open architecture, avoid modifying the Windows operating
system, since this may cause problems for the instrument's user interface. Please follow these
recommendations:
•
Do not load any version of Windows not provided by LeCroy. If you load any Windows 2000
service packs from Microsoft, please be advised that LeCroy cannot guarantee trouble-free
operation afterwards.
•
Avoid modifying Control Panel settings.
•
Do not change the color resolution (24 bit) or screen size (800 x 600 pixel) settings.
•
After you load third-party software applications, if your scope does not work properly try
reloading the instrument software from the CD shipped with the scope.
•
Do not modify or remove any system fonts; doing so may affect the readability of the dialogs.
•
Do not change any display properties like Background, Appearance, Effects, or Settings.
Functionality of the scope or screen saver may be affected.
•
Do not make any changes to the Windows folder.
•
Do not make any changes to the BIOS settings.
•
Do not make any changes to the Windows power management system.
Windows Repair Disk
Before you install any hardware or software on your instrument, LeCroy strongly recommends
that you create an Emergency Repair Disk. During a system rebuild, the repair process relies on
information that is saved in the systemroot\repair folder. You must not change or delete this folder.
You only need a blank 1.44 MB floppy disk to create an Emergency Repair Disk (ERD).
To create an Emergency Repair Disk
1.
In the task bar at the bottom of the screen, touch
Start
,
Programs
,
Accessories
,
System Tools
,
Backup
.
2.
In the "Tools" menu, touch
Emergency Repair Disk
.
3.
Follow the instructions displayed on the screen.
Содержание 6000 SERIES
Страница 59: ...WR6K OM E Rev A ISSUED October 2003 57 4 Select a language 5 Click Next when the Wizard appears ...
Страница 60: ...Operator s Manual 58 ISSUED October 2003 WR6K OM E Rev A 6 Select Complete setup 7 Click Install ...
Страница 65: ...WR6K OM E Rev A ISSUED October 2003 63 Proper Orientation of Drive ...
Страница 131: ...WR6K OM E Rev A ISSUED October 2003 129 Example ...
Страница 141: ...WR6K OM E Rev A ISSUED October 2003 139 ...
Страница 236: ...Operator s Manual 234 ISSUED October 2003 WR6K OM E Rev A Example 6 ...
Страница 247: ...WR6K OM E Rev A ISSUED October 2003 245 In this figure the panel has been pasted onto the Excel sheet for comparison ...
Страница 261: ...WR6K OM E Rev A ISSUED October 2003 259 ...
Страница 286: ...Operator s Manual 284 ISSUED October 2003 WR6K OM E Rev A ...
Страница 304: ...Operator s Manual 302 ISSUED October 2003 WR6K OM E Rev A ...
Страница 307: ...WR6K OM E Rev A ISSUED October 2003 305 Convolve two signals ...
Страница 327: ...WR6K OM E Rev A ISSUED October 2003 325 How JitterTrack s Interval Error works when Clock Mode is selected ...
Страница 348: ...Operator s Manual 346 ISSUED October 2003 WR6K OM E Rev A ...
Страница 398: ...Operator s Manual 396 ISSUED October 2003 WR6K OM E Rev A Setting Up the Line Voltage and Current Signals ...
Страница 402: ...Operator s Manual 400 ISSUED October 2003 WR6K OM E Rev A ...