ruby standard configuration User Manual
Version: 6.4.0/2
83/179
8. Operation
8.9.6
Limiter
A separate Limiter is available for all sources.
Ø
To access the limiter parameters, press an
ACCESS
key followed by
LIM
on the Central Module.
Surface Controls (Limiter)
DisplayDock
The following parameters are available for the Limiter:
·
LIM
- on/off for the limiter: red = on.
·
THRS
- threshold from -93dB to +27dB.
·
RLS -
release time from 10ms to 5000ms.
The Limiter graph on DisplayDock includes a green ball which represents the output level of the Limiter.
This changes dynamically as the signal level varies, and so is extremely helpful when adjusting parameters.