ruby standard configuration User Manual
Version: 6.4.0/2
26/179
6. Installation
The following procedure can be used fit a new IO card or exchange an IO card once the unit is operational. All
cards are hot-pluggable, and so the exchange can be performed while the device is powered.
To remove and replace the screws you will need a small flat-blade screwdriver (not supplied).
The IO cards carry highly sensitive electronic components, and should be handled with care.
ALWAYS
observe the following procedures:
·
Discharge yourself before touching an IO card.
·
Wear conductive safety-shoes and grounding wristbands to reduce the risk of electrostatic
discharging.
·
DO NOT bend the cards.
1
.
Using a Phillips PH1 driver, unfasten the two diagonally opposite screws which hold the card, or cover
plate, in place.
2
.
Gently pull out the card from the frame, or remove the cover plate:
Spare cover plates should be stored safely so that they can be reused later if a card is removed.