
- 36 -
TAPPING FUNCTION
In the event that the batching instrument is not equipped with the speed “slow” it is possible to use
this function to slow down the product batching in the final phase (through opening and closing
cycles of the SET contact) and to increase the accuracy. Set in
parameter the product amount
you want to batch with the tapping function enabled.
SLOW ON
(from 0 to 9.9; default: 0): time in which the SET relay remains closed during the SLOW
phase. By setting 0, the function is disabled.
COMMUNICATION INTERFACE
WRITING
READING
Write the value in W1.
Send command 1023 to CMDR.
Send command 1022 to CMDR.
Read the value in R1.
SLOW OFF
(from 0 to 9.9; default: 0): time in which the SET relay remains open during the SLOW
phase. By setting 0, the function is disabled.
COMMUNICATION INTERFACE
WRITING
READING
Write the value in W1.
Send command 1025 to CMDR.
Send command 1024 to CMDR.
Read the value in R1.
AUTOTARE
(from 0 to 999; default: 0): autotare enabling (automatic tare at batching start); the autotare
will be updated every as many cycles of a single batching sequence as are set in this parameter. By
setting 0, the function is disabled.
This operation is possible only if the gross weight is lower than the minimum weight (
),
otherwise the
alarm is activated.
COMMUNICATION INTERFACE
WRITING
READING
Write the value in W1.
Send command 1027 to CMDR.
Send command 1026 to CMDR.
Read the value in R1.