- 37 -
AUTOTARE DELAY
(from 0 to 99.9; default: 0): the instrument waits for this time, after the starting of the
formula, before performing the autotare and starting the batching.
This parameter is available only if
is enabled.
COMMUNICATION INTERFACE
WRITING
READING
Write the value in W1.
Send command 1029 to CMDR.
Send command 1028 to CMDR.
Read the value in R1.
STABLE TARE
(default:
): autotare enabled at stable weight.
-
: if autotare enabled, zero-setting at batching start is done after a possible delay time and
only when the weight is stable.
-
: if autotare enabled, zero-setting is done right after the delay time.
This parameter is available only if
is enabled.
COMMUNICATION INTERFACE
WRITING
READING
Write the enabling status* in W1.
Send command 1031 to CMDR.
Send command 1030 to CMDR.
Read the enabling status* in R1.
*1= enabled; 0= disabled. It is lost at power-off.
CONSUMPTION FOR EACH FORMULA
(default
): enabling consumption memory (total batched quantity) for each formula.
-
: consumption enabled
-
: consumption disabled.
COMMUNICATION INTERFACE
WRITING
READING
Write the enabling status* in W1.
Send command 1053 to CMDR.
Send command 1052 to CMDR.
Read the enabling status* in R1.
*1= enabled; 0= disabled. It is lost at power-off.