- 27 -
BATCHING (LOAD program)
INTRODUCTION TO THE OPERATION
The instrument is able to load automatically a settable amount of product on the weighing structure,
driving the batching organ (including two-speed) through the PRESET and SET contacts.
The instrument has the following features:
-
99 settable formulas (see section
FORMULAS PROGRAMMING
);
-
automatic fall calculation (see section
FALL
);
-
autotare at batching start (see section
AUTOTARE
);
-
tolerance error control (see section
TOLERANCE
);
-
precision batching through slow function (see section
SLOW
);
-
precision batching through tapping function (see section
TAPPING FUNCTION
);
-
consumption storage (see section
CONSUMPTION
).
BATCHING START:
via external contact or remotely via fieldbus.
CONSUMPTION STORAGE:
the instrument, at the end of every batching, stores the consumed amount for each formula.
Consumptions value can be viewed directly on instrument display or via the communication protocol
when the instrument is in standby mode.
ALARM MANAGEMENT:
if an alarm occurs during the batching, the instrument shows the alarm on the display and waits for
operator intervention to abort or continue the batching.
BATCHING SEQUENCE
The batching process consists of the following steps:
-
batching sequence programming;
-
batching start;
-
batching execution;
-
waiting phase;
-
cycle end phase.