- 3 -
GROSS WEIGHT (GW) - NET WEIGHT (NW)
The weight values are expressed as positive integer numbers, including decimal figures, but without
decimal point. Read the Status Register to obtain information about sign and possible errors on the
weight.
EXCHANGE REGISTERS (R1, R2, W1, W2)
These registers are used for instrument management operations. Two read and two write exchange
registers are available.
STATUS REGISTER 1 (SR1)
Bit 0
Load cell error
Bit 8
Net weight negative sign
Bit 1
AD converter malfunction
Bit 9
Peak weight negative sign
Bit 2
Maximum weight exceeded by 9 divisions
Bit 10
Net display mode
Bit 3
Gross weight higher than 110%
of full scale
Bit 11
Weight stability
Bit 4
Gross weight beyond 999999
or less than -999999
Bit 12
Weight within ±¼ of a division
around ZERO
Bit 5
Net weight beyond 999999
or less than -999999
Bit 13
Bit 6
Bit 14
Bit 7
Gross weight negative sign
Bit 15
STATUS
REGISTER 2 (SR2)
Bit 0
Preset tare enabled
Bit 4
Bit 1
Instrument ready
Bit 5
Bit 2
Bit 6
Bit 3
Bit 7
INSTRUMENT STATUS (IS)
This register is used for the LOAD program only.
0
Instrument at rest (weight displaying)
13
alarm
1
Batching not possible/programming mode
14
alarm
2
Batching phase
15
alarm
3
Waiting phase
16
alarm
4
Cycle end phase
17
alarm
5
Batching paused
18
alarm