11: User Authentication
SLB™ Branch Office Manager User Guide
192
UID
A unique numeric identifier the system administrator assigns to each user.
Valid UIDs are 101-4294967295.
Note:
The UID must be unique. If it is not, SLB branch office manager
automatically increments it. Starting at 101, the SLB device finds the next
unused UID.
Listen Ports
The device ports that the user may access to view data using the
connect
listen
command. Enter the port numbers or the range of port numbers (for
example, 1, 5, 8, 10-15).
Data Ports
The device ports with which the user may interact using the connect direct
command. Enter the port numbers or the range of port numbers.
Clear Port Buffers
The device port buffers the users may clear using the
set locallog
clear
command. Enter the port numbers or the range of port numbers.
Access Outlets
The outlets the user may monitor and configure.
Enable for Dial-back
Select to grant a local user dial-back access. Users with dial-back access can
dial into the SLB branch office manager and enter their login and password.
Once the SLB unit authenticates them, the modem hangs up and dials them
back. Disabled by default.
Dial-back Number
The phone number the modem dials back on depends on this setting for the
device port. The user is either dialed back on a fixed number (specified on the
Device Port - Settings page), or on a number that is associated with the user’s
login (specified here).
Escape Sequence
A single character or a two-character sequence that causes the SLB unit to
leave direct (interactive) mode. (To leave listen mode, press any key.)
A suggested value is
Esc+A
(escape key, then uppercase "A" performed
quickly but not simultaneously). You would specify this value as
\
x1bA
, which
is hexadecimal (
\
x
) character 27 (
1B
) followed by an
A
.
This setting allows the user to terminate the
connect direct
command on
the command line interface when the endpoint of the command is deviceport,
tcp, or udp.
Break Sequence
A series of 1-10 characters users can enter on the command line interface to
send a break signal to the external device. A suggested value is
Esc+B
(escape key, then uppercase “B” performed quickly but not simultaneously).
You would specify this value as
\
x1bB
, which is hexadecimal (
\
x
) character 27
(
1B
) followed by a
B
.
Custom Menu
If custom menus have been created, you can assign a default custom menu to
the user. The custom menu will display at login.
Note:
In the Local Users table, if the menu assigned to a local user no longer
exists, it is marked with an asterisk (*).
Display Menu at Login
If custom menus have been created, select to enable the menu to display
when the user logs into the CLI.
Password /
Retype Password
When a user logs into the SLB branch office manager, the SLB unit prompts
for a password (up to 64 characters). The sysadmin establishes that password
here.
Password Expires
If not selected, allows the user to keep a password indefinitely. If selected the
user keeps the password for a set period. (See the section,
for information on specifying the length of time
before the password expires.)
Allow Password Change
Select to allow the user to change password.
Change Password on
Next Login
Indicate whether the user must change the password at the next login.
Содержание 100-120 VAC SLB
Страница 114: ...8 Device Ports SLB Branch Office Manager User Guide 114 Figure 8 4 Device Ports Settings ...
Страница 131: ...8 Device Ports SLB Branch Office Manager User Guide 131 Figure 8 10 Devices Power Outlets ...
Страница 174: ...9 USB Port SLB Branch Office Manager User Guide 174 Figure 9 3 Devices USB Modem ...
Страница 227: ...12 Maintenance SLB Branch Office Manager User Guide 227 Figure 12 1 Maintenance Firmware Configurations ...