8: Device Ports
SLB™ Branch Office Manager User Guide
130
3. Click the
Apply
button to save the changes.
Console Port Commands
Go to
Console Port Commands (on page 286)
to view CLI commands which correspond to the
web page entries described above.
Power Outlets
The SLB branch office manager has eight outlets that can provide power to other units in an IT
environment. Each outlet can be configured and controlled through the SLB unit. The SLB device
can issue an SNMP trap if the total current for all eight outlets exceeds a specified threshold.
To configure a power outlet:
1. Click the
Devices
tab and select the
Power Outlets
option. The following page displays:
Note:
Clicking any of the red P1 through P8 buttons, located at the top of each page
displayed, allows controlled configuration of the power outlets.
Group Access
If undefined, any group can access the console port. If one or more groups are
specified (groups are delimited by the characters ' ' (space), ',' (comma), or ';'
(semicolon)), then any user who logs into the console port must be a member of
one of the specified groups, otherwise access will be denied. Users authenticated
via RADIUS may have a group (or groups) provided by the RADIUS server via the
Filter-Id attribute that overrides the group defined for a user on the SLB. A group
provided by a remote server must be either a single group or multiple groups
delimited by the characters ' ' (space), ',' (comma), ';' (semicolon), or '=' (equals) -
for example "group=group1,group2;" or "group1,group2,group3".
Содержание 100-120 VAC SLB
Страница 114: ...8 Device Ports SLB Branch Office Manager User Guide 114 Figure 8 4 Device Ports Settings ...
Страница 131: ...8 Device Ports SLB Branch Office Manager User Guide 131 Figure 8 10 Devices Power Outlets ...
Страница 174: ...9 USB Port SLB Branch Office Manager User Guide 174 Figure 9 3 Devices USB Modem ...
Страница 227: ...12 Maintenance SLB Branch Office Manager User Guide 227 Figure 12 1 Maintenance Firmware Configurations ...