6 | Function description
The user interface
6.4.4.3 The parameter window [System settings]
In the [System settings] parameter window, you can set the requirements to auto-
matically record and cool the soldering process at the end of the process. With re-
gard to this, please read the chapter [The window [Online HR 600] [
85]]. The
settings made here affect all soldering processes.
ü
To display the [System settings] parameter window:
a) Enable the [System settings] tab.
System ready
Soldering
Placement
Profile library
Archive
Save target position
Actual parameters
Data table
System settings
System info
System settings
Parameters
Recording
Cooling
Automatic process recording start
Automatic process recording end
Top cooling auto ON (at end of process)
Bottom cooling auto ON (at end of process)
When process starts
At temperature below 150°C
ON
On and auto. off after 90 s
Factory settings
Value
X-Axis
Y-Axis
Z-Axis
Angle of rotation
-86765
149787
0
0
Fig. 24:
The [System settings] parameter window
To record start/stop:
ü
To determine when to start and stop the process recording:
a) In the register [Parameters], you can see a list of editable parameters.
b) In the Value] column, click on a line.
c) Select an entry from the drop-down menu.
ð
The setting has been changed and is immediately active.
Please note: [Tinit] is the temperature above which the profile control starts. It is
displayed in the [Online-HR 600] graph window as [TI].
To automate cooling:
In the [Parameters] column, you can see a list of editable parameters.
ü
Define when cooling is to be automatically switched on and off:
a) In the Value] column, click on a line.
b) Select an entry from the drop-down menu.
ð
The setting has been changed and is immediately active.
To restore factory settings:
ü
To restore the factory settings of the [System settings] tab:
a) Click on the [Factory settings] button.
ð
The factory settings have been loaded and are immediately active.
Ersa GmbH
3BA00207_01 Operating Instructions HR 600_2 | Rev. 3
82 / 169
Содержание HR 600/2
Страница 2: ......
Страница 6: ......
Страница 16: ...1 Introduction Information about this manual Ersa GmbH 3BA00207_01 Operating Instructions HR 600_2 Rev 3 16 169...
Страница 22: ...2 Technical data Available options Ersa GmbH 3BA00207_01 Operating Instructions HR 600_2 Rev 3 22 169...
Страница 28: ...3 For your safety Retrofitting and changes Ersa GmbH 3BA00207_01 Operating Instructions HR 600_2 Rev 3 28 169...
Страница 146: ...7 Spare and wear parts Spare parts Ersa GmbH 3BA00207_01 Operating Instructions HR 600_2 Rev 3 146 169...