8
TECHNICAL DATA
74
IFC 050
www.krohne.com
09/2016 - 4002184003 - MA IFC 050 R03 en
Current output
Current output
Current output
Current output
Output data
Flow
Settings
Without HART
Without HART
Without HART
Without HART
®
Q = 0%: 0
…
20 mA; Q = 100%: 10
…
21.5 mA
Error identification: 20
…
22 mA
With HART
With HART
With HART
With HART
®
Q = 0%: 4
…
20 mA; Q = 100%: 10
…
21.5 mA
Error identification: 3
…
22 mA
Operating data
Operating data
Operating data
Operating data
Basic I/Os
Basic I/Os
Basic I/Os
Basic I/Os
Active
Observe connection polarity.
U
int, nom
= 20 VDC
I
≤
22 mA
R
L
≤
750
Ω
HART
®
at terminals A
Passive
Observe connection polarity.
U
ext
≤
32 VDC
I
≤
22 mA
U
0
≤
2 V at I = 22 mA
R
L, max
= (U
ext
- U
0
) / I
max
HART
®
at terminals A
HART
HART
HART
HART
®
Description
HART
®
protocol via active and passive current output
HART
®
version: V5
Universal Common Practice HART
®
parameter: completely supported
Load
≥
250
Ω
at HART
®
test point;
Note maximum load for current output!
Multi-drop mode
Yes, current output = 4 mA
Multi-drop address adjustable in operation menu 1
…
15