ELECTRICAL CONNECTIONS
4
39
IFC 050
www.krohne.com
09/2016 - 4002184003 - MA IFC 050 R03 en
Pulse/frequency output passive
•
U
ext
≤
32 VDC
•
f
max
in the operating menu set to f
max
≤
100 Hz:
I
≤
100 mA
R
L
≤
47 k
Ω
closed:
U
0
≤
0.2 V at I = 10 mA
U
0
≤
2 V at I = 100 mA
open:
I
≤
0.05 mA at U
ext
= 32 V
•
f
max
in operating menu set to 100 Hz < f
max
≤
10 kHz:
(over range up to f
max
≤
12 kHz)
I
≤
20 mA
R
L
≤
10 k
Ω
for f
≤
1 kHz
R
L
≤
1 k
Ω
for f
≤
10 kHz
closed:
U
0
≤
1.5 V at I = 1 mA
U
0
≤
2.5 V at I = 10 mA
U
0
≤
5 V at I = 20 mA
open:
I
≤
0.05 mA at U
ext
= 32 V
Use shielded cables!
•
The minimum load impedance R
L, min
is calculated as follows:
R
L, min
= (U
ext
- U
0
) / I
max
•
Can also be set as status output; for the electrical connection refer to status output
connection diagram.
INFORMATION!
•
For frequencies above 100 Hz, shielded cables are to be used in order to reduce effects from
electrical interferences (EMC).
•
Shielding takes place at the electrical connection (S) of the output terminal block.
INFORMATION!
•
Independent of connection polarity.
•
The output is open if the signal converter is not powered.
Figure 4-15: Pulse/frequency output passive P
p