6.8.4.33
Captive Portal configuration max bytes allowed to output/receive
This command configures the maximum number of octets the user is allowed to receive. After this limit
has been reached the user will be disconnected. If the value is set to 0 then the limit is not enforced.
Syntax
max-output-octets <0-4294967295>
no max-output-octets
Default Setting
0
Command Mode
Captive Portal Instance
6.8.4.34
Captive Portal configuration max total allowed to transmit and receive
This command configures the maximum number of octets the user is allowed to transfer, i.e., the sum of
octets transmitted and received. After this limit has been reached the user will be disconnected. If the
value is set to 0, then the limit is not enforced.
Syntax
max-total-octets <0-4294967295>
no max-total-octets
Default Setting
0
Command Mode
Captive Portal Instance