Korenix Technology Co., Ltd.
Industrial
Layer 3 Managed Ethernet Switch
_____________________________________________________________________________
Industrial Layer 3 Managed Ethernet SwitchUser Manual
Page: 1085/1246
9.4.7.12
Configuring MAC Access Control List Rule Configuration Page
Selection Criteria
MAC ACL
- Select the MAC ACL for which to create or update a rule.
Rule
- Select an existing rule or select 'Create New Rule' to add a new Rule. New rules cannot be
created if the maximum number of rules has been reached. For each rule, a packet must match all
the specified criteria in order to be true against that rule and for the specified rule action
(Permit/Deny) to take place.
Configurable Data
Rule
- Enter a whole number in the range of (1 to 255) that will be used to identify the rule.