Korenix Technology Co., Ltd.
Industrial
Layer 3 Managed Ethernet Switch
_____________________________________________________________________________
Industrial Layer 3 Managed Ethernet SwitchUser Manual
Page: 1233/1246
9.7.7.3
ConfiguringInterface Configuraiton
Selection Criteria
Interface
- Select the interface for which data is to be displayed or configured.
Admin Mode
- Select Enable or Disable to set the administrative status of PIM for the
specified interface in the router. The default is Disable.
BSR Border
- Select enable or disable to set BSR border status on the selected interface. This
field is applicable for PIMSM only.
Configurable Data
Hello Interval (secs)
- Enter the time (in seconds) between the Transmission of which PIM Hello
messages on this interface. The valid values are from (0 to 18000) seconds. The default value is
30 seconds.
Join/Prune Interval (secs)
- Enter the frequency (in seconds) at which PIM Join/Prune
messages are transmitted on this PIM interface. This field is applicable for PIMSM only. The valid
values are from (0 to 18000) seconds. The default value is 60 seconds.
DR Priority
- Enter the DR priority for the selected interface. This field is applicable for PIMSM
only. The valid values are from (0 to -2) The default value is 1.
Command Buttons
Submit
- Send the updated configuration to the router. Configuration changes take effect
immediately. These changes will not be retained across a power cycle unless a save is
performed.
Refresh
- Refresh the data on the screen with the present state of the data in the switch.