Korenix Technology Co., Ltd.
Industrial
Layer 3 Managed Ethernet Switch
_____________________________________________________________________________
Industrial Layer 3 Managed Ethernet SwitchUser Manual
Page: 1146/1246
9.6.3.5
Configuring Area Range
Selection Criteria
Area ID
- Selects the area for which data is to be configured.
Configurable Data
IP Address
- Enter the IP Address for the address range for the selected area.
Subnet Mask
- Enter the Subnet Mask for the address range for the selected area.
LSDB Type
- Select the type of Link Advertisement associated with the specified area and
address range. The default type is 'Network Summary'.
Advertisement
- Select enable or disable from the pull-down menu. If you selected enable
the address range will be advertised outside the area via a Network Summary LSA. The
default is enable.
Remove
- Check box to remove the particular entry from the table.
Non-Configurable Data
Area ID
- The OSPF area.
IP address
- The IP Address of an address range for the area.
Subnet Mask
- The Subnet Mask of an address range for the area.
LSDB Type
- The Link Advertisement type for the address range and area.
Advertisement
- The Advertisement mode for the address range and area.
Command Buttons
Create
- Send the updated configuration to the switch. Configuration changes take effect
immediately. These changes will not be retained across a power cycle unless a save is
performed. The new address range will be added to the display in the non-configurable data area.
Delete
- Removes the specified address range from the area configuration.
Refresh
- Refresh the data on the screen with the present state of the data in the switch.