MDC-5000 Series
Chapter 7 System and Maintenance menu operation
0093153004-00
7-5
7.8
BACKUP of Setup data (Cannot be used while transmitting)
By saving setup data to the internal memory or external memory, the initial setup and all settings are
saved, in the event that the radar needs to be reinitialized or some setup changes been made, user can
go back to the original settings by restoring from memory.
Backup of setup data should be saved after initial setup.
In case of malfunction of display where re-initialization must be done, restore of backup data completed
at the time of original setup will bring all proper settings and tuning setup back to normal operation.
Internal save of setup data
To save data internally at the time of setup,
1
Press MENU key to display
“Menu”.
Select [MAINTENANCE] => [BACKUP] => [SETUP SAVE] => [GO], and press ENT key.
To restore from internally backup after re-initialization,
1
Press MENU key to display
“Menu”.
Select [MAINTENANCE] => [BACKUP] => [SETUP LOAD] => [GO], and press ENT key.
External save of setup and map data
To save setup and map data externally, this information can be later used to restore after a possible
malfunction.
The external memory uses an SD memory card.
CAUTION: Please do not use the SD memory card which is loaded with software program files.
To perform external backup to SD card,
1
Insert SD memory card in the upper card reader of the Processor unit. [SD Card (1)] is labeled
beside the upper card reader.
2
Press MENU key to display
“Menu”.
Select [MAINTENANCE] => [BACKUP] => [SD CARD] => select [SETUP SAVE], [MARK SAVE],
[TGT TRACK SAVE] or [OWN TRACK SAVE] => [CANCEL] or [GO], and press ENT key.
When SD memory card not inserted, [SD CARD] menu is shaded menu and cannot be operated.
To restore from SD card backup after re-initialization,
1
Insert SD card that was used to store settings in above procedure in the upper card reader of the
Processor unit. [SD Card (1)] is labeled beside the upper card reader.
2
Press MENU key to display
“Menu”.
Select [MAINTENANCE] => [BACKUP] => [SD CARD] => select [SETUP LOAD], [MARK LOAD],
[TGT TRACK LOAD] or [OWN TRACK LOAD] => [CANCEL] or [GO], and press ENT key.
When SD memory card not inserted or no data found on the card, [SD CARD] menu is shaded
menu and cannot be operated.
Содержание MDC-5004
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 28: ... This page intentionally left blank ...
Страница 33: ...MDC 5000 Series Chapter 1 Display and Operation 0093153004 00 1 5 This page intentionally left blank ...
Страница 38: ... This page intentionally left blank ...
Страница 110: ... This page intentionally left blank ...
Страница 114: ... This page intentionally left blank ...
Страница 142: ... This page intentionally left blank ...
Страница 150: ... This page intentionally left blank ...
Страница 156: ...Chapter 10 Specifications MDC 5000 Series 0093153004 00 10 6 Unit mm inch RB809 ...
Страница 188: ... This page intentionally left blank ...
Страница 192: ......