Heinrichs Messtechnik GmbH
OPERATING MANUAL TMU-W / UMC4
Page 87 of 118
SIMULATION functional class
The functional class SIMULATION is comprised of the functions for simulating the outputs. If simulation is
activated, all output signals will be generated based on the selected type of simulation. The peripherals
connected to the device can be tested without a flowing product.
Simulation will be deactivated automatically if the operator switched the device off or did not touch any control
unit keys for about 10 minutes. Simulation can also be activated and controlled via HART
®
commands.
SIMULATION
Simulation
on / off
Simulation
status output
SIMULATION
functional class
Simulation
[off]
_________________
on
off
Status output
[on]
_________________
on
off
Simulation
pulse output
Set frequency
0009.0 Hz
Simulation
curr. output I1
Simulation
curr. output I2
Set I1
I1 = 12.00 mA
Set I2
I2 = 12.00 mA
Simulation
direct / QMabs
Simulation
[direct]
_______________
direct
QM, D, T
Simulation
QMabs
Set QMabs
+0900.000 kg/h
Simulation
density
Set density
0500.000 g/l
Simulation
temperature
Set temperature
+090 °C