Heinrichs Messtechnik GmbH
OPERATING MANUAL TMU-W / UMC4
Page 81 of 118
7.2.9.3
Status output 2 assignment
Instead of current output 2 a second status output may be selected for custody transfer operations.
It has the same assignment possibilities as status output 1. However, it cannot be used as a pulse output.
After selecting the Status output assignment function, press “Enter” to display the current assignment.
Output 2 assigned to
[not available]
The current assignment will be displayed and can be changed by toggling the arrow keys.
The operator can choose between the following settings:
Standard setting
o
Not available
Flow direction recognition:
o
Forward flow
o
Reverse flow
Limiting values
o
MIN QM
o
MAX QM
o
MIN density
o
MAX density
All limiting values and error detection
o
Alarm
Pressing the “Enter” key confirms the entry.