OPERATING MANUAL TMU-W / UMC4
PULSE OUTPUT functional class
The PULSE OUTPUT functional class is comprised of the functions regarding the pulse output.
PULSE OUTPUT
Pulse or frequency
output
Pulse output unit
PULSE OUTPUT
functional class
Output of
[Pulses]
_______________
Pulses
Frequncy
Accumulation of
1.0 kg
______________
g
kg
t
m³
cm³
l
USG
UKG
USB
lbs
ston
lton
ft³
acft
oz
flox
xxQM
xxQV
Pulse value
1 pulse per
[1.0] unit
________________
0.001
0.01
0.1
1.0
10.0
100.0
Pulse width
Pulse width
0050.0 ms