OPERATING MANUAL TMU-W / UMC4
7.2.11.4
Direct simulation of outputs
If the operator selected the setting “Direct simulation” described in Section 7.2.11.2, “Direct simulation” on
page 88, the following four possible settings will affect the output behaviour during measured value simulation,
where all measured values are simulated at the same time.
7.2.11.4.1
Status output simulation
The Status output simulation function allows the operator to purposefully activate the status output.
Press “Enter” to display the current state.
Status output
[off]
The current setting will be displayed and can be changed by toggling the arrow keys
The operator can toggle between “on” and “off”.
Pressing the “Enter” key confirms the entry.
7.2.11.4.2
Pulse output simulation
The Pulse output simulation function allows the operator to define a frequency to be assigned to the pulse
output. After selecting this function and pressing “Enter”, the following selection field will be displayed:
Set frequency
0210.0 Hz
The current value will be displayed and can be changed by toggling the arrow keys
The frequency range of the pulse output can be set from 6 Hz to 1100 Hz.
Pressing the “Enter” key confirms the entry.
7.2.11.4.3
Simulation current output I1
This function allows the operator to define a current for current interface 1. Press “Enter” to display the set
current.
Set I1
I1 = 10.50 mA
The current value will be displayed and can be changed by toggling the arrow keys.
Values in the range from 3.8 mA to 22.6 mA are permitted.
Pressing the “Enter” key confirms the entry.
7.2.11.4.4
Simulation current output I2
As described in Section 7.2.11.4.3, current output 2 can also be configured.