STATus Command
KIKUSUI Electronics Corp.
PWR-01 Interface Manual
STAT:OPER:INST:ISUM<n>:PTR
Sets the positive transition of the OPERation:INSTrument:ISUMmary<n> subregis-
ter.
Use <n> to specify the channel number.
For example, to specify channel 2, send the "STAT:OPER:INST:ISUM2:PTR" com-
mand.
Command
STATus:OPERation:INSTrument:ISUMmary<n>:PTRansition <NRf>
STATus:OPERation:INSTrument:ISUMmary<n>:PTRansition?
Parameter
Value: 0 to 32767
Response
Returns the positive transition of the OPERation:INSTrument:ISUMmary<n> sub-
register in NR1 format.
QUEStionable status register
The QUEStionable status register is a 16-bit register that stores information related
to the questionable events and status during PWR-01 operation.These register bits
may indicate problems with the measured data of the PWR-01.
Bit Bit
weight
Bit name
Description
0
1
OVP (OV)
Overvoltage protection has been activated
1
2
OCP (OC)
Overcurrent protection has been activated
2
4
AC (PF)
Low AC input protection has been activated
3
8
Front Panel OCP (FOCP)
Front panel overcurrent protection has been acti-
vated
4
16
Over Temperature Protection
(OT)
Overheat protection has been activated
5
32
Shut Down protection (SD) Shut down
6
64
PARAllel protection (PARA) Incorrect parallel operation connection has been
activated
7
128
SENSing protection (SENS) Incorrect sensing connection protection has been
activated
8
256
NOT USED
--
9
512
NOT USED
--
10 1024 NOT USED
--
11 2048 Internal commuication failure
(12C)
--
12 4096 NOT USED
--
13 8192 NOT USED
--
14 16384 WatchDOG protection
(WDOG)
Communication monitor has been activated
15 32768 NOT USED
Always zero