SYSTem Command
KIKUSUI Electronics Corp.
PWR-01 Interface Manual
SYST:EXT:STATOUT:CC:POL
Sets the polarity of the status output signal for constant-current mode.
This command is invalid while a sequence is running.
Command
SYSTem:EXTernal:STATOUT:CC:POLarity <character>
SYSTem:EXTernal:STATOUT:CC:POLarity?
Parameter
Value:
POSitive
High in CC mode
NEGative
Low in CC mode (default)
(Example)
SYST:EXT:STATOUT:CC:POL NEG
Response
Returns the polarity of the status output signal in character format in response to
SYST:EXT:STATOUT:CC:POL?.
SYST:EXT:STATOUT:CV:POL
Sets the polarity of the status output signal for constant-voltage mode.
This command is invalid while a sequence is running.
Command
SYSTem:EXTernal:STATOUT:CV:POLarity <character>
SYSTem:EXTernal:STATOUT:CV:POLarity?
Parameter
Value:
POSitive
High in CV mode
NEGative
Low in CV mode (default)
(Example)
SYST:EXT:STATOUT:CV:POL NEG
Response
Returns the polarity of the status output signal in character format in response to
SYST:EXT:STATOUT:CV:POL?.