GLOBal Command
KIKUSUI Electronics Corp.
PWR-01 Interface Manual
GLOB:INIT:TRAN
Starts the setting change (TRANsient) trigger function of all the channels in the
same multichannel domain.
If trigger source is set to IMM, the change starts immediately. If set to BUS, the
change starts after waiting for a software trigger. If set to TRIGIN, the change starts
after waiting for a hardware trigger.
This command cannot be executed simultaneously with the PROGram subsystem.
Insert a wait of at least 200 ms after sending the GLOB:INIT:TRAN command.
Command
GLOBal:INITiate[:IMMediate]:TRANsient
Related Command
TRIG:TRAN:SOUR
GLOB:OUTP
Turns the output on and off of all the channels in the same multichannel domain.
This command is invalid when a protection function is activated.
OUTP ON is invalid while a sequence is running. OUTP OFF terminates the se-
quence and turns the output off.
Insert a wait of at least 200 ms after sending the GLOB:OUTP command.
Command
GLOBal:OUTPut[:STATe][:IMMediate] <boolean>
Parameter
Value:
ON(1)
Output on
OFF(0)
Output off (default)
Settings are reset to default when the GLOB:*RST command is sent.
(Example)
GLOB:OUTP 1