1-8 Setup
PFX2000
Connecting the power cord of the PFX2331 Unit Frame
Keep in mind that the product is designed for Overvoltage Category II.
1.
Check that the AC power supply meets the AC input speci
fi
cations of
the PFX2331.
2.
Turn off the power switch.
3.
Prepare the terminals at the AC power supply end of the power cord as
The AC power supply end of the power cord that comes with the PFX2331
comes in a cut condition. Remove the insulation so that a plug or crimp termi-
nal can be attached to the wires.
4.
Attach a plug or crimp terminals to the power cord.
5.
Connect the power cord to the AC LINE connector on the rear panel.
6.
Connect the power cord to a power outlet or a switchboard.
If you are connecting the power cord to a switchboard, turn off the switchboard
switch beforehand.
Fig. 1-2Power cord of the PFX2331
Nominal input rating: 200 VAC to 240 VAC, 50/60 Hz, single phase
Power consumption:
1
500 VA (at rated output)
N:
White or blue
L:
Black or brown
(GND):
Green or green/yellow
To the AC LINE