PFX2000
Specifications 5-5
Protection function
Item
PFX2011
PFX2021
Overvoltage (over-
charge) protection
Software OVP
Shuts OFF the output of the corresponding channel. Released by
resetting the alarm.
Hardware OVP
Shuts OFF the output of the corresponding channel. Released by
resetting the alarm.
Undervoltage
(overdischarge)
protection
Software UVP
Shuts OFF the output of the corresponding channel. Released by
resetting the alarm.
Hardware UVP
Shuts OFF the output of the corresponding channel. Released by
resetting the alarm.
Overcharge capacity protection
(OAH)
Shuts OFF the output of the corresponding channel. Released by
resetting the alarm.
DUT overtemperature protection
(OTP)
Shuts OFF the output of the corresponding channel. Released by
resetting the alarm.
PS board error (PS Alm)
Hardware overvoltage and overheat
CD board overheat
(OHP)
Reverts to idle status after changing to normal temperature.
CD board error (CD Alm)
Occurs due to causes such as an open-circuit in the current line or
line drop of the current line.
DUT (battery) connection error
(Connection Error)
Displays a warning before the execution of the test, if battery is not
connected.
Communication error
Internal communication error
Watchdog timer
Shuts off the output when tripped and the test is aborted. 419 ms
cycle.
AC power line error
(AC off)
Detects short interruption of approx. 50 ms.
Shuts off the output of the corresponding channel.
Alarm monitoring
OVP, UVP, OAH, OTP, PS Alm, OHP, CD Alm, Connection Error,
Communication Error, and AC off.