1-12 Setup
PFX2000
1.6.2
Installation Procedure
The procedure below uses the PFX2011 charge/discharge power supply unit as an
example. The procedure is similar for the PFX2021.
1.
Remove the louver. See Fig. 1-4.
2.
Pull down the lever toward you.
3.
Carry the charge/discharge power supply unit with both hands as
shown in Fig. 1-4, and slowly insert the unit into the desired slot.
When you insert the unit a third of the way in, a lock mechanism is activated
and you can no longer insert the unit.
4.
When the lock mechanism is activated, lift the unit using the hand
under the unit and press in.
The lock is released. Insert the unit until the lever you pulled forward (the sec-
tion marked with an asterisk in Fig. 1-4) touches the unit frame.
5.
Pull up on the lever and push the unit in further.
If power to the unit frame in on, all the LEDs on the unit's panel illuminate in
orange, and then all LEDs except the POWER/STANDBY LED turn off. If the
unit does not enter this status (STANDBY status), there is a problem on the
unit.
6.
Check that the panel surface of the unit is nearly
fl
at with the rack
mount bracket surface.
7.
Use the screws that comes with the unit frame to
fi
x the unit to the
frame.
•
The unit is securely grounded to the frame by
fi
xing the unit to the frame
using screws.
For safety reasons, be sure to
fi
x the unit using screws.
8.
Attach the louver.
WARNING