PFX2000
Setup 1-21
TP-BUS connection procedure
■
Wiring the TP-BUS connector
•
The TP-BUS allows hot plug. You can insert or remove the TP-BUS con-
nector even when the power to the device is on.
However, do not insert or remove connectors while the charge/discharge
test is in progress as this may cause a malfunction.
• Connect the control unit so that it is at the end of the TP-BUS. The control unit
does not have a TERMN switch and the termination is always on. Therefore, it
must be connected to the end of the TP-BUS. For details, see section 1.8.2, “Set-
ting the TERMN Switch.”
• Allow extra length of cable between devices. After wiring the TP-BUS connector,
you will wrap the TP-BUS cable once around a core that cames with the package.
If extra length of cable is not available, you will not be able to attach the core.
1.
Insert the TP-BUS connector (plug) provided to the TP-BUS connector
on the rear panel. See Fig. 1-12 (a).
The succeeding work involved in connecting the wires becomes easier by
fi
x-
ing the connector.
2.
Use a wire stripper to remove 7 mm of the covering from the wires.
3.
Insert the wires into the connectors as shown in Fig. 1-12 (b) and (c).
TP-BUS has no polarity. You do not have to match the polarities between units.
4.
Use the screwdriver to turn the connector screw and
fi
x the wires in
place.
5.
Check that the wires do not come loose.
•
Check that the wires are not short-circuited.
•
Check that the conducting sections of the wires are not touching the chas-
sis. If it is, damage to the device may result.
6.
Connect the other connectors in a similar fashion.
CAUTION
NOTE
CAUTION