5-14 Specifications
PFX2000
5.1.3
General Specifications
a.
Safety is designed and evaluated with the charge/discharge power supply unit installed in the ded-
icated frame.
b.
This product is a Class I instrument. Be sure to ground the protective conductor terminal of the
product. The safety is not guaranteed unless the product is grounded properly.
Item
PFX2011
PFX2021
Tempera-
ture range
Spec guaranteed tem-
perature range
18
°
C to 28
°
C
Operating tempera-
ture range
0
°
C to 40
°
C
Storage temperature
range
-10
°
C to 60
°
C
Humidity
range
Operating humidity
range
30 % to 80 % RH (no condensation)
Storage humidity
range
20 % to 80 % RH (no condensation)
Insulation
resistance
Between AC input and
chassis
100 M
Ω
or more at 500 VDC
Between unit output
and chassis
20 M
Ω
or more at 50 VDC
Withstand
voltage
Between AC input and
chassis
1500 VAC for 1 minute at 50 mA or less
AC input
Received from the dedicated frame.
Power
con-
sump-
tion
At rated
output
300 VAmax when two channels
are charged at their speci
fi
ed rat-
ings.
800 VAmax when charged at the
speci
fi
ed rating (1 unit alone).
At no-load
60 VAmax when two channels
are in standby status.
50 VAmax in standby status (1
unit alone).
TP-BUS interface
Addresses
1 to 120
1 to 119 (odd numbers only)
Safety
ab
Complies with the requirements of the standard below.
IEC61010-1:2001
Class I
Pollution degree 2
Miscella-
neous
Dimensions
Approx. 85.5 W
×
177 H
×
523 D mm
Approx. 85.5 W
×
177 H
×
560 D mm maximum
Weight
Approx. 4 kg
Approx. 4.5 kg
Accessories